TTL TO RS485 (B) User Guide

Overview

TTL TO RS485 (B) is an industrial-grade rail-mounted electrically isolated TTL-to-RS485 serial converter.

Feature

  • Compatible with TTL/RS422 standard, converting the TTL signal into a balanced differential RS422 signal, supporting half-duplex communication
  • Compatible with 3.3V ~ 5V TTL signal level, with anti-reverse connection and anti-over-voltage circuit on the power supply side
  • Onboard unibody power supply isolation, provides stable isolated voltage and needs no extra power supply for the isolated terminal
  • Onboard unibody digital isolation, allows signal isolation, high reliability, strong anti-interference, and low power consumption
  • Onboard TVS (Transient Voltage Suppressor), effectively suppresses surge voltage and transient spike voltage in the circuit, and anti-electrostatic
  • Onboard resettable fuse and protection diodes, ensures the current/voltage stable outputs, provide over-current/over-voltage protection, improve shock resistance
  • On-board RS485 input and output 120R resistors with built-in jumper caps for switching enable
  • Industrial rail-mount ABS case design, small in size, easy to install, and cost-effective

Parameters

ModelGalvanic isolated TTL To RS485 converter
Power PortPower supply3.3V ~ 5V
Interface Protectionanti-over-discharge, reverse-proof
Device interfaceCompatible with TTL / RS422 standard
TTL InterfaceInterface typeScrew terminal
Transmission distanceAbout 10m
Transmission modelPoint to point
RS422 InterfaceInterface typeScrew terminal
Interface ProtectionProvide 600W lightningproof, surge-suppress and 15KV ESD protection
Terminal Resistance120R, enabled/disabled via switch
Transmission DistanceAbout 1200m
Transmission Modepoint-to-multipoint (up to 32 nodes, it is recommended to use repeaters for 16 nodes or more)
Product AppearanceCaseRail-mount ABS case, suitable for 35mm DIN rail
Dimensions91.6 × 58.7 × 23.3mm

Primary Function

Convert the TTL signal into a balanced differential RS485 signal, which can be used for interface conversion and node expansion, and can also be used to extend the communication distance.

Interface Introduction



Communication Connection Diagram

TTL convert to RS485, point to point, half-duplex communication, suitable for interface conversion


TTL convert to RS485, point-to-multipoint, half-duplex communication, suitable for expanding nodes


Two groups TTL To RS485 conversion, point-to-point, half-duplex communication, suitable for extending the communication distance of TTL


Dimensions


Hardware Test

Test Note

Test Environment: PC (Windows).
Accessories required for testing:

Test Hardware Connection

The RS422 interface of TTL TO RS485 (B) is connected to the PC through the USB to RS422 conversion cable. The TTL interface of TTL TO RS485 (B) is connected with the TTL of USB TO TTL. The USB port of USB TO TTL is connected to the same PC for the self-receiving test. The schematic diagram of the hardware connection is as follows:

Note: The RS485 interface of this product is also equipped with 120R Switch, the default is on, the user can set it according to the needs (set up to open, set down to NC), if signal isolation is required, you can set GND is also connected to ground.

On the PC, open two SSCOM serial port debugging assistants, open the corresponding port number, set the same baud rate, and click Send at regular intervals to send and receive normally. The screenshot of the software test is as follows:


Note: RS485 is a half-duplex communication, and the sending and receiving test cannot be performed at the same time.